Alem L.
We serviced a
WHIRLPOOL DRYER
Model WED4800BQ1
Near Westlake, Ohio 44145
Alem L.
Job Details:
05/07/2026
Cc unit taking 2-3 loads to dry clothes. Verified and found that dryer was heating and working as should. Also noticed that the vent he had on the back was pretty long and dryer was pushed back crimping the vent. Recommended customer to get a shorter vent and not to push unit all the way back. If problem continues even after that it is due to airflow and vents have to be clogged up with lint. Unit is working as designed opt test good.
We serviced a
WHIRLPOOL WASHER
Model NTW4516FW4
Near Lorain, Ohio 44055
Alem L.
Job Details:
05/07/2026
Cc drain pump running continuously. Confirmed. Ran diagnostics and found error code f3e1 pressure system fault. Didnt have W11603811 in truck so I used W11603810 from truck stock all I did was place the new control board into old case. Tested unit and everything working as should opt test good. ; used 1 W11603810 (CONTROL w/CORECORECORE) from stock
We serviced a
MAYTAG WASHER
Model MVW6500MBK0
Near Elyria, Ohio 44035
Alem L.
Job Details:
05/07/2026
"Cc unit lock, senses, and then goes to done and drains. Confirmed. Replaced actuator from truck stock to see if it would fix problem but nothing also checked capacitor and was reading as should. Ran diagnostics and found error code f2e3 ACU/ Ui mismatch. Ordering control board and encoder assembly. ; ordrng 1 W11633362 (Control board) and 1 W11627516 (Encoder assembly), used 1 W11481722 (actuator) from stock"
We serviced a
WHIRLPOOL WASHER
Model WTW5057LW1
Near North Ridgeville, Ohio 44039
Alem L.
Job Details:
05/07/2026
Cc unit locks then goes straight to done. Verified and found that capacitor would only hum. Replaced capacitor and also the actuator because I noticed actuator didnt want engage either. Tested unit and everything working as should opt test good.
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRF560SMHZ06
Near Cleveland, Ohio 44102
Alem L.
Job Details:
05/07/2026
"Cc unit not cooling in ff section. Verified and found that there was ice on evaporator cover and fan wasnt running took off ice from evaporator cover and off fan and fan started running again. Noticed half a frost pattern let unit run for a little awhile to see if a frost pattern would form and there was a complete frost pattern but still no cold air going into ff section. Ordering damper. Part showing out of stock, office to reschedule. ; ordrng 1 W11087463 (Damper)"
HollyO
Avon Lake, Ohio
KITCHENAID MICROWAVE
KMHC319EBS4
Alem was excellent! Timely, efficient, considerate of our home. He quickly diagnosed the problem and did the repairs. He was polite, friendly and knowledgeable. Fred’s Appliance is lucky to have him.
Thank you for your kind words about Alem! We're glad to hear he provided excellent service and represented our company well. We truly appreciate your feedback and your business.
05/07/2026
Saundra
Avon, Ohio
GE REFRIGERATOR
GNE27JYMWFFS
Great service as always
Thank you for your kind words! We're glad you had a great experience with our service at Fred's Appliance. Your satisfaction is our priority.
04/30/2026
Tracy S.
Cleveland, Ohio
ROPER DRYER
RED4516FW0
I would definitely recommend Fred’s Appliance. They supplied excellent communication prior and up-to my appointments. Alem was courteous, professional and was able to fix my appliance quickly.
Thank you for the kind words! We are thrilled to hear about your positive experience with Alem. Your recommendation means a lot to us!
04/30/2026
Scott
Westlake, Ohio
MAYTAG WASHER
MTW7200RW1
Very helpful and friendly. Took time to insure we understood the operation of the appliance.
Thank you for your kind words! We are glad we could help you with understanding your appliance operation. Let us know if you need anything else!
04/29/2026
Debs
Lorain, Ohio
MAYTAG WASHER
MVW5430MW1
Took care of the issue with professionalism and friendly service.
Thank you for your feedback! We strive to provide professional and friendly service at all times. Your satisfaction is our priority.
04/23/2026